- E31 — Moisture sensor feedback frequency is too high, so the dryer cannot judge dryness correctly on sensor cycles.
- E32 — Moisture sensor feedback frequency is too low, so sensor dry cycles may stop early or run oddly.
- E42 — Door sensing error: the dryer is not getting a correct signal that the door is closed.
- E51 — Motor relay failure: the relay that runs the drum motor has failed, so the motor may not run or may run intermittently.
- E52 — The drum motor has stopped or will not start.
- E61 — Heater relay failure: the relay controlling the heating element has failed, so the dryer cannot control heat.
- E63 — The control detected a ground short at the heating element (the element is shorted to ground).
- E64 — Open heating element circuit: the element circuit is broken, so the dryer tumbles without heat.
- E65 — The high limit thermostat has tripped open too many times on an electric dryer, indicating repeated overheating.
- E66 — The thermal limiter has tripped, cutting the heat circuit as protection against overheating.
- E71 — Outlet thermistor failure: the temperature sensor at the outlet is out of range (E71 or E72 on some models).
- E91 — Communication error between the user interface and the main electronic control board.
- EF1 — Blocked exhaust vent: airflow is restricted, so the dryer overheats or dries poorly and flags the vent.
- EF3 — Maximum dry time has expired and the clothes are still wet, a strong sign of restricted airflow or weak heat.