- E24 — The control thermistor (temperature sensor) circuit is shorted, so the dryer cannot read exhaust temperature correctly.
- E25 — The control thermistor (temperature sensor) circuit is open, so the dryer gets no temperature reading.
- E42 — Door sensing error: the dryer thinks the door is open or is not getting a proper signal from the door switch.
- E4A — Program timeout: the drying time has exceeded the maximum time allowed for the selected cycle, usually because clothes are still wet.
- E5B — Heater fault with no heating: the control thermistor reading does not change, meaning the dryer tumbles but does not heat.
- E61 — Heater relay failure: the relay that switches the heating element has failed, so heat control is lost.
- E63 — The heating element is shorted to ground (the cabinet), a fault the control detects in the heater circuit.
- E64 — Heater open circuit: the heating element or its wiring is electrically open (broken), so the dryer tumbles with no heat.
- E65 — The high limit thermostat has tripped too many times, which points to repeated overheating, usually from restricted airflow.
- E66 — Thermal limiter open circuit: the outlet thermal limiter (thermal fuse) has tripped, cutting off heat as a safety measure.
- E68 — A key (button) on the control panel is stuck closed, so the control keeps reading a constant press.
- E8C — The high-limit thermostat has tripped too often: the dryer is overheating, usually from poor airflow through the vent.
- EF1 — Blocked exhaust vent: the dryer detects restricted airflow and cannot exhaust hot, moist air properly.