What the E5 code means

On GE Profile DPVH890 dryers (technical service manual): Outlet Open - the outlet thermistor circuit is open; check and replace if necessary.

Likely causes

  1. Open/failed outlet thermistor
  2. Disconnected thermistor connector
  3. Broken wire in the thermistor harness

How to fix it — step by step

  1. Unplug the dryer and let it cool
  2. Try one cycle after restoring power
  3. If E5 returns, arrange service for thermistor/harness replacement