Lennox Furnace 2 + 3 Error Code

What the 2 + 3 code means

On Lennox G61MPV furnaces with the SureLight control, flash code 2 + 3 means the low pressure switch failed open — it did not close to prove inducer draft.

Likely causes

  1. Blocked intake or exhaust vent
  2. Clogged or frozen condensate drain
  3. Weak inducer motor
  4. Failed pressure switch or cracked hose

How to fix it — step by step

  1. Clear snow, ice, leaves or debris from the outdoor intake and exhaust terminations
  2. Check the condensate drain and trap for clogs or freezing
  3. Reset power once (off 30 seconds, then on)
  4. If the code returns, call a technician to test the inducer and pressure switch — do not bypass the switch