Maytag Dryer F4 E3 Error Code
What the F4 E3 code means
Restricted airflow (the F-code form of AF): the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The dryer continues to run while the code is shown.
Likely causes
- Clogged lint screen
- Vent crushed, kinked or clogged with lint
- Vent run with too many turns
- Blocked outside vent hood
How to fix it — step by step
- Clean the lint screen thoroughly
- Check the vent behind the dryer is not crushed or kinked
- Clean lint from the whole vent run to the outside hood
- Touch any key to clear the code, then run a Timed Dry heated cycle to check drying
Parts that commonly fix the F4 E3 code
This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.