Pentair Pool heater Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 22 codes covered.
Shop Pentair Pool heater parts at RepairClinic
- 126 — On Pentair MasterTemp gas pool heaters, code 126 means the water temperature sensor is shorted, per the manual error and fault code table.
- BROWNOUT — On Pentair UltraTemp heat pump pool heaters, BROWNOUT means the 24 VAC supply voltage to the control board is low; the manual lists a bad…
- E01 — On Pentair MasterTemp gas pool heaters, E01 means the water temperature sensor is open. Clear the error by pressing the HEATER OFF button.
- E05 — On Pentair MasterTemp gas pool heaters, E05 means the stack flue sensor is open. The front panel buttons are disabled for this fault and…
- E06 — On Pentair MasterTemp gas pool heaters, E06 means the stack flue sensor is shorted. The front panel buttons are disabled for this fault and…
- ERR AFS — On Pentair MasterTemp gas pool heaters, ERR AFS means the air flow switch is open - the blower is not on or air through it is being…
- ERR AGS — On Pentair MasterTemp gas pool heaters, ERR AGS is automatic gas shutoff - water temperature after the second pass through the heat…
- ERR HLS — On Pentair MasterTemp gas pool heaters, ERR HLS means the high temperature limit switch is open - water temperature after the first pass…
- ERR IGN — On Pentair MasterTemp gas pool heaters, ERR IGN means the Ignition Control Module was not able to ignite the heater. Clear it by pressing…
- ERR PS — On Pentair MasterTemp (and Sta-Rite Max-E-Therm) gas pool heaters, ERR PS means the water pressure switch is open - no water flow through…
- ERR SFS — On Pentair MasterTemp gas pool heaters, ERR SFS means the stack flue temperature is excessive - more than 480F. The front panel buttons are…
- FIVE ALARMS — On Pentair UltraTemp heat pump pool heaters, FIVE ALARMS indicates that 5 faults have occurred in one hour. It automatically resets in one…
- HIGH REFRIG — On Pentair UltraTemp heat pump pool heaters, HIGH REFRIG means the refrigerant high pressure switch is open.
- HIGH WATER TEMP — On Pentair UltraTemp heat pump pool heaters, HIGH WATER TEMP means the water temperature is above 108F.
- LOW AMBIENT TEMP — On Pentair UltraTemp heat pump pool heaters, LOW AMBIENT TEMP means the refrigerant temperature sensor indicates air temperature is too low…
- LOW REFRIG — On Pentair UltraTemp heat pump pool heaters, LOW REFRIG means the refrigerant low pressure switch is open.
- LOW WATER FLOW — On Pentair UltraTemp heat pump pool heaters, LOW WATER FLOW means the pressure switch sensing water flow is open - the heat pump is not…
- LOW WATER TEMP — On Pentair UltraTemp heat pump pool heaters, LOW WATER TEMP means the water temperature is below 40F.
- SUCTION TH OPEN — On Pentair UltraTemp heat pump pool heaters, SUCTION TH OPEN means the defrost (suction) thermistor circuit is open.
- SUCTION TH SHORT — On Pentair UltraTemp heat pump pool heaters, SUCTION TH SHORT means the defrost (suction) thermistor circuit is shorted.
- WATER THERM OPEN — On Pentair UltraTemp heat pump pool heaters, WATER THERM OPEN means the water temperature thermistor circuit is open.
- WATER THERM SHORT — On Pentair UltraTemp heat pump pool heaters, WATER THERM SHORT means the water temperature thermistor circuit is shorted.