Raypak Pool heater Water Sw Open

What this problem usually means

On Raypak Digital gas pool heaters (206A, 266A, 336A and 406A), Water Sw Open means the water pressure switch is open because the heater is not sensing enough water flow or pressure to fire.

Likely causes

  1. pump off or losing prime
  2. dirty filter or clogged strainer
  3. closed or partly closed valves
  4. faulty water pressure switch

How to fix it — step by step

  1. Confirm the circulation pump is running and primed
  2. Clean or backwash the filter and empty the pump strainer basket
  3. Open all valves in the heater loop fully
  4. Try the heater once with full flow restored
  5. If the message stays with good flow, call a pool technician to test the pressure switch

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.