Trane Furnace 9 flashes

What this problem usually means

Trane uses this flash count on two different control families, so note which LED is flashing (red LED = single-stage control; green LED = two-stage control). On single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) using the replacement integrated furnace control covered in Trane guide 18-CH92D1-1A-EN, 9 flashes means an igniter relay fault — the control's igniter relay or igniter circuit has failed. On two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), 9 flashes means a grounding or reversed-polarity fault — the 115V supply polarity is reversed or grounding is improper.

Likely causes

  1. Single-stage models: failed igniter relay on the control board
  2. Single-stage models: open or failed hot surface igniter
  3. Single-stage models: loose igniter wiring connection
  4. Two-stage models: reversed line and neutral at the furnace
  5. Two-stage models: poor or missing earth ground
  6. Two-stage models: recent electrical work

How to fix it — step by step

  1. Note which LED is flashing and confirm the thermostat is calling for heat and the furnace has power
  2. Reset power once (off 30 seconds, then on) and listen for the normal start sequence
  3. Do not rewire the furnace electrical connections yourself — on two-stage models this code is a polarity/grounding fault
  4. Call an HVAC technician (or an electrician for the polarity/grounding fault) to test the igniter circuit or correct the wiring

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Trane furnace problems

See all Trane furnace codes & guides →