Hayward Pool pump Drive overload

What this problem usually means

On Hayward TriStar VS 900 variable-speed pool pumps (Check System message), Drive overload means motor current is too high; the manual says to check the impeller, diffuser, shaft seal and motor for issues or binding, and notes this error can only be reset by cycling power.

Likely causes

  1. debris binding the impeller
  2. worn shaft seal or diffuser
  3. motor binding or failing

How to fix it — step by step

  1. Turn power off at the breaker - Drive overload is cleared by cycling power, not just Stop/Resume
  2. With power off, empty the strainer basket and check for visible debris at the impeller inlet
  3. Restore power once and try to start the pump
  4. Do not disassemble the wet end unless you are comfortable resealing it
  5. If overload returns, call a pool/spa technician

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Hayward pool pump problems

See all Hayward pool pump codes & guides →