Jandy Pool heater FAULT- HIGH LIMIT Error Code
What the FAULT- HIGH LIMIT code means
On Jandy JXi gas pool heaters, FAULT- HIGH LIMIT means water inside the heater exceeded its internal high-limit setting, or a high-limit switch has faulted. The JXi has two high limits, about 135F at the heat exchanger first pass and 150F at the outlet.
Likely causes
- restricted water flow through the heater
- dirty filter or pump running too slow
- stuck thermal regulator valve
- faulty high-limit switch
How to fix it — step by step
- Turn the heater off and let the water in the heater cool
- Confirm the pump is running with strong flow and clean the filter
- Check valves are open and pump speed is adequate
- Try the heater once after it has cooled
- If the fault repeats, stop and call a pool technician to test the high-limit switches
Parts that commonly fix the FAULT- HIGH LIMIT code
- high limit switch - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.