Jandy Pool heater FAULT- PUMP Error Code
What the FAULT- PUMP code means
On Jandy JXi gas pool heaters, FAULT- PUMP is a status message, not a failure: the heater is in Maintain Temp mode while the filter pump is currently switched off, and Jandy states no service is required.
Likely causes
- filter pump off in Maintain Temp mode
- pump timer between run periods
How to fix it — step by step
- Check whether the filter pump is scheduled to be off
- Run the pump if you want the heater to maintain temperature
- No reset or repair is needed for this message alone
- Call a technician only if the pump itself will not run
Parts that commonly fix the FAULT- PUMP code
This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.