Trane Furnace 7 flashes

What this problem usually means

Trane uses this flash count on two different control families, so note which LED is flashing (red LED = single-stage control; green LED = two-stage control). On single-stage furnaces (XR80, XR90, XR95, XB80, XB90 families) with the integrated furnace control (IFC), 7 flashes means a gas valve circuit error — the control detects a fault in the gas valve circuit, such as voltage present when the valve should be off. On two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2), 7 flashes means external lockout — retries exceeded, after the furnace failed to establish flame through all ignition retries.

Likely causes

  1. Single-stage models: shorted gas valve wiring
  2. Single-stage models: failed gas valve solenoid
  3. Single-stage models: failed control board gas valve relay
  4. Two-stage models: failed hot surface igniter
  5. Two-stage models: dirty flame sensor
  6. Two-stage models: gas supply off or interrupted

How to fix it — step by step

  1. Turn furnace power off and note the code and which LED is flashing for the technician
  2. Confirm the gas shutoff valve to the furnace is open and other gas appliances work
  3. Do not attempt to test or rewire the gas valve circuit
  4. If you smell gas, leave the house and call the gas utility from outside
  5. Call a technician to test the gas valve, igniter, flame sensor and control board

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Trane furnace problems

See all Trane furnace codes & guides →