- AF — Restricted airflow: the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The dryer keeps running while…
- F1 E1 — Motor relay stuck on the electronic control board: the control detects an internal motor relay failure, and the relay is part of the…
- F1 E3 — Control mismatch: the control console and electronic control board do not match, or the wrong control board was installed.
- F2 E1 — Stuck button: a button on the user interface control is stuck down.
- F2 E4 — Control console / user interface failure: the console has an internal or software fault (shown as F2 E4 or F2 E5 on these models).
- F2 E5 — Control console / user interface failure: the console has an internal or software fault (shown as F2 E4 or F2 E5 on these models).
- F3 E1 — Exhaust thermistor failure: the control detects a failed exhaust temperature sensor (open or shorted).
- F3 E2 — Moisture sensor failure: the control is not getting a proper signal from the moisture sensor bars inside the drum.
- F3 E3 — Inlet thermistor failure: the control detects a failed inlet temperature sensor.
- F3 E6 — Moisture sensor failure on Duet Hybrid (heat pump) dryers: the control detects a fault in the moisture sensor circuit.
- F4 E1 — Heating fault: on Cabrio steam models this is a heating element failure, and on 2015 Cabrio models a heater relay failure.
- F4 E2 — Heating fault: on Cabrio steam models this is a heating element failure, and on 2015 Cabrio models a heater relay failure (shown as F4 E1…
- F4 E3 — Restricted airflow, the F-code form of the AF warning: the lint screen or vent is clogged or the vent is crushed or kinked.
- F4 E4 — Low line 2 voltage / voltage supply error: the L2 leg of the 240-volt power supply is missing.
- F6 E2 — Communication failure: there is no communication between the electronic control board and the control console (shown as F6 E2 or F6 E3).
- F6 E3 — Communication failure: communication between the electronic control board and the user interface control has been lost (shown as F6 E2 or…
- F9 E1 — Drain system failure on Duet Hybrid (heat pump) dryers, which pump out condensed water instead of venting it.
- L2 — Low or no line voltage: a problem with the home power supply may be keeping the dryer's heater from turning on. The dryer keeps running…
- PF — Power failure: the drying cycle was interrupted by a power failure.