York Furnace 8 red flashes

What this problem usually means

Flame was lost 5 times (4 recycles) during the heating cycle on York furnaces with the red/green/amber LED control. The furnace locks out for one hour and then restarts.

Likely causes

  1. low gas pressure
  2. faulty gas valve
  3. dirty flame sensor

How to fix it — step by step

  1. Check the thermostat is set to Heat and the furnace power switch and breaker are on
  2. Confirm the manual gas shutoff valve near the furnace is open (handle parallel to the pipe)
  3. Turn power off for 30 seconds, then back on, and allow one retry cycle
  4. Do not keep resetting a furnace that repeatedly fails to light
  5. If it locks out again, call a licensed HVAC technician and note the code

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related York furnace problems

See all York furnace codes & guides →