What the 21 code means

Gas heating lockout. On Payne furnaces such as the PG92ESA, PG95ESA and PG96VTA, code 21 means 24 VAC was sensed on the gas valve when it should not be there; the manual's procedure is to turn off power and wait 5 minutes to retry. The control can no longer guarantee the valve will stay shut.

Likely causes

  1. Gas valve relay stuck closed on the control board
  2. Miswire or short to the gas valve wire

How to fix it — step by step

  1. Turn the furnace off at the service switch and leave it off
  2. Do not repeatedly cycle power trying to clear this code
  3. Do not touch the gas valve or its wiring
  4. Call a technician - the control board or gas valve circuit must be tested and repaired

Parts that commonly fix the 21 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.