What the 25 code means
Invalid model selection or setup error, documented on the Payne PG96VTA variable-speed two-stage furnace. If code 25 flashes only 4 times at power-up, the control is missing its model plug PL4 and is defaulting to the model stored in memory; continuous flashing means the plug is missing with no valid stored model, a setup switch is wrong, or two different models were twinned.
Likely causes
- Model plug PL4 missing (common after a replacement control board)
- Setup switch SW1-1 or SW1-6 left in the wrong position
- Two different furnace models twinned together
- Incorrect service replacement control
How to fix it — step by step
- Note the code and when it first appeared (especially if a board was just replaced)
- Do not move setup switches or swap plugs yourself
- Cycle power once at the service switch; if 25 returns, stop
- Call the technician who serviced the furnace to fit the correct model plug and set the switches
Parts that commonly fix the 25 code
- model plug - Shop at RepairClinic
- control board - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.