Trane Furnace E2.1 Error Code

What the E2.1 code means

On Trane S-series furnaces with a seven-segment display (S9X1, S9X2, S9B1 and S8X1, S8X2), code E2.1 is retry lockout — flame was never sensed after 3 ignition tries in one call for heat, followed by a one-hour lockout.

Likely causes

  1. Failed or cracked hot surface igniter
  2. Gas supply off or gas valve not opening
  3. Dirty flame sensor

How to fix it — step by step

  1. Wait out the one-hour lockout or reset power once
  2. Confirm the gas shutoff to the furnace is open and other gas appliances work
  3. Replace a dirty air filter
  4. If it locks out again, call a technician to test the igniter, gas valve and flame sensor

Parts that commonly fix the E2.1 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Trane furnace error codes

See all Trane furnace codes & guides →