Trane Furnace 1 flash

What this problem usually means

On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: flame sensed when no flame should be present — a flame signal exists while the gas valve should be closed. Note this count differs from single-stage Trane boards.

Likely causes

  1. Gas valve leaking or stuck open
  2. Shorted flame sensor wiring
  3. Failed control board

How to fix it — step by step

  1. Turn furnace power off and close the gas shutoff to the furnace
  2. Do not keep resetting the furnace
  3. If you smell gas, leave the house and call the gas utility
  4. Call a technician to test the gas valve and flame-sense circuit

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.