Trane Furnace 1 flash
What this problem usually means
On Trane two-stage furnaces (XV80, XV90, XV95, XL80, XL90 families, *UD2/*DD2) the green LED counts the fault: flame sensed when no flame should be present — a flame signal exists while the gas valve should be closed. Note this count differs from single-stage Trane boards.
Likely causes
- Gas valve leaking or stuck open
- Shorted flame sensor wiring
- Failed control board
How to fix it — step by step
- Turn furnace power off and close the gas shutoff to the furnace
- Do not keep resetting the furnace
- If you smell gas, leave the house and call the gas utility
- Call a technician to test the gas valve and flame-sense circuit
Parts that commonly fix it
- gas valve - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- control board - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.