York Furnace 7 red flashes

What this problem usually means

Flame could not be established on York furnaces with the red/green/amber LED control. The no-light condition occurred 3 times during the call for heat before locking out for one hour.

Likely causes

  1. low gas pressure
  2. faulty gas valve
  3. faulty hot surface ignitor
  4. burner problem

How to fix it — step by step

  1. Check the thermostat is set to Heat and the furnace power switch and breaker are on
  2. Confirm the manual gas shutoff valve near the furnace is open (handle parallel to the pipe)
  3. Turn power off for 30 seconds, then back on, and allow one retry cycle
  4. Do not keep resetting a furnace that repeatedly fails to light
  5. If it locks out again, call a licensed HVAC technician and note the code

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related York furnace problems

See all York furnace codes & guides →