Goodman Furnace EE0 Error Code
What the EE0 code means
Lockout from excessive ignition retries on newer Goodman single-stage furnaces with the alphanumeric display control (service manual RS6621008). The furnace failed to establish flame or lost flame after establishment and locked out.
Likely causes
- no gas supply or closed gas valve
- failed hot surface igniter
- dirty flame sensor
- blocked flue or weak inducer
How to fix it — step by step
- Check the thermostat is set to Heat and the furnace power switch and breaker are on
- Confirm the manual gas shutoff valve near the furnace is open (handle parallel to the pipe)
- Turn power off for 30 seconds, then back on, and allow one retry cycle
- Do not keep resetting a furnace that repeatedly fails to light
- If it locks out again, call a licensed HVAC technician and note the code
Parts that commonly fix the EE0 code
- hot surface igniter - Shop at RepairClinic
- flame sensor - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.