Goodman Furnace Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 24 problems covered.
Shop Goodman Furnace parts at RepairClinic
- 1 flash — System lockout because ignition retries were exceeded on Goodman GMES96-series furnaces with the red LED diagnostic board. The furnace…
- 10 flashes — Open fuse on Goodman GMES96-series furnaces. The low-voltage fuse on the control board has opened, usually because of a short in the…
- 11 flashes — Igniter open on Goodman GMES96-series furnaces. The control sees an open igniter circuit, so the igniter cannot heat up to light the…
- 12 flashes — Inducer relay error or improper grounding on Goodman GMES96-series furnaces. The control cannot run the inducer relay correctly or detects…
- 2 flashes — Pressure switch stuck closed on Goodman GMES96-series furnaces. The control found the pressure switch closed at startup when it should be…
- 3 flashes — Pressure switch stuck open on Goodman GMES96-series furnaces. The inducer ran but the pressure switch never closed to prove draft, so…
- 4 flashes — Open main or auxiliary temperature limit switch on Goodman GMES96-series furnaces. The furnace overheated and a limit safety opened, most…
- 5 flashes — Flame sensed for more than 4.25 seconds with the gas valve de-energized on Goodman GMES96-series furnaces. The control still sees flame (or…
- 6 flashes — Open rollout temperature limit switch on Goodman GMES96-series furnaces. The rollout safety tripped, meaning flame escaped the burner…
- 7 flashes — Low flame sense signal on Goodman GMES96-series furnaces. Flame is present but the flame sensor signal is too weak for the control to trust…
- 8 flashes — Igniter relay fault on Goodman GMES96-series furnaces. The control detected a fault in the igniter relay circuit on the integrated control…
- 9 flashes — Twinning fault on Goodman GMES96-series furnaces. This applies to twinned (two furnaces sharing one duct system) installations where the…
- E10 — Grounding fault or poor neutral connection on newer Goodman furnaces with the alphanumeric display control.
- E11 — Open rollout switch on newer Goodman single-stage furnaces with the alphanumeric display control. The rollout safety opened because flame…
- EE0 — Lockout from excessive ignition retries on newer Goodman single-stage furnaces with the alphanumeric display control (service manual…
- EE1 — Pressure switch circuit closed at the start of a heat cycle on newer Goodman single-stage furnaces with the alphanumeric display control.…
- EE2 — Pressure switch circuit not closed when it should be on newer Goodman single-stage furnaces with the alphanumeric display control. Draft…
- EE3 — Primary limit circuit open on newer Goodman single-stage furnaces with the alphanumeric display control. The furnace overheated, most often…
- EE4 — Flame sensed with no call for heat on newer Goodman single-stage furnaces with the alphanumeric display control. Goodman documents this as…
- EE5 — Open fuse or short in low-voltage wiring on newer Goodman single-stage furnaces with the alphanumeric display control.
- EE6 — Flame-sense signal is low on newer Goodman single-stage furnaces with the alphanumeric display control. Goodman lists this as a…
- EEE — Internal control board fault (internal faults or IRQ loss) on newer Goodman single-stage furnaces with the alphanumeric display control.
- EEn — Igniter open on newer Goodman single-stage furnaces with the alphanumeric display control. The igniter circuit is open, so the furnace…
- Rapid flash — Reverse polarity on Goodman GMES96-series furnaces. The 115V line polarity to the furnace or control is reversed, so the control will not…