Kenmore Dryer PS Error Code
What the PS code means
Power supply error on Kenmore 796-series (LG-built) electric dryers: the power cord is not connected correctly, for example the neutral (white) and L2 (red) wires are on the wrong terminals, so the control protects itself.
Likely causes
- Power cord wired incorrectly at the terminal block
- House power supply incorrect
- Loose power cord connection
How to fix it — step by step
- Turn off power at the breaker and unplug the dryer
- Check the power cord connection at the back of the dryer against the installation instructions
- Correct the wiring or have an electrician do it if you are not confident
- Restore power and try a cycle
Parts that commonly fix the PS code
This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.