Kenmore Dryer Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 19 codes covered.
Shop Kenmore Dryer parts at RepairClinic
- AF — Restricted or low airflow on Kenmore 110-series (Whirlpool-built) Kenmore Elite dryers: the vent is crushed, kinked or clogged with lint…
- d80 — Exhaust vent about 80% blocked on Kenmore 796-series (LG-built) dryers: the CHECK VENT system has detected a restriction in the external…
- d90 — Exhaust vent about 90% blocked on Kenmore 796-series (LG-built) dryers: the ductwork is severely restricted, drying will be slow and the…
- d95 — Exhaust vent about 95% blocked on Kenmore 796-series (LG-built) dryers: the ductwork is almost completely blocked, which is a fire risk.…
- dE — Door switch error on Kenmore 796-series (LG-built) steam dryers: the control cannot confirm the door is closed and working.
- E1 — Thermistor failure on Kenmore 110-series dryers with electronic controls (Whirlpool-built platform): Sears PartsDirect lists E1 for this…
- E3 — Control mismatch on Kenmore 110-series dryers with electronic controls: the user interface and main electronic control board do not match…
- F:01 — Main electronic control board failure on Kenmore Elite dryers (110-series Whirlpool-built platform). The control is not processing…
- F:02 — Keypad or user interface failure on Kenmore Elite dryers (110-series Whirlpool-built platform): a key is stuck or the interface is not…
- F:20 — Heater relay failure on Kenmore Elite dryers (110-series Whirlpool-built platform): the heating circuit is not being controlled correctly…
- F:22 — Outlet thermistor failure, open circuit, on Kenmore Elite dryers (110-series Whirlpool-built platform): the control detects an electrically…
- F:23 — Outlet thermistor failure, shorted circuit, on Kenmore Elite dryers (110-series Whirlpool-built platform): the control detects an…
- F:24 — Inlet thermistor failure on Kenmore Elite dryers (110-series Whirlpool-built platform): the control detects a problem with the inlet…
- F:25 — Inlet thermistor failure on Kenmore Elite dryers (110-series Whirlpool-built platform): the control detects a problem with the inlet…
- gAS — Gas supply problem on Kenmore 796-series (LG-built) gas dryers: the gas supply is off or there is a gas service issue, so the dryer cannot…
- L2 — Low or missing line voltage on Kenmore 110-series (Whirlpool-built) Kenmore Elite dryers: the drum may turn but the heater may not turn on…
- PF — Power failure on Kenmore 110-series (Whirlpool-built) and many 796-series Kenmore dryers: power was interrupted during a cycle. The dryer…
- PS — Power supply error on Kenmore 796-series (LG-built) electric dryers: the power cord is not connected correctly, for example the neutral…
- tE1 — Temperature sensor failure on Kenmore 796-series (LG-built) dryers: the manual for 796 models lists tE1 or tE2 as a temperature sensor…