Lennox Furnace E241 Error Code
What the E241 code means
On newer Lennox furnaces (EL296, SL280, SLP98, ML296 and similar) showing three-digit codes from the Lennox Residential Communicating Systems Alert Code Guide, E241 means flame out of sequence and still present — the control senses flame when the gas valve should be closed. Lennox's documented first step is shutting off the gas.
Likely causes
- Gas valve leaking or stuck open
- Failed control board
- Shorted flame-sense wiring
How to fix it — step by step
- Shut off the gas supply to the furnace and turn furnace power off
- Do not try to restart the furnace
- If you smell gas, leave the house and call the gas utility from outside
- Call a technician to test the gas valve before the furnace is used again
Parts that commonly fix the E241 code
- gas valve - Shop at RepairClinic
- control board - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.