Carrier Furnace 43 Error Code

What the 43 code means

Low-heat pressure switch open while the high-heat pressure switch is closed - a contradictory pressure switch state on two-stage Carrier furnaces such as the 58CTA and 58CVA. (On the older 4-LED variable-speed 58MVP platform, code 43 instead denotes a pressure switch calibration fault.)

Likely causes

  1. Low-heat pressure switch stuck open
  2. Disconnected or obstructed pressure tubing
  3. Mis-wired pressure switches
  4. Low inlet gas pressure (if a low gas pressure switch is fitted)

How to fix it — step by step

  1. Check the condensate drain line and trap for a clog or standing water
  2. Check outdoor vent terminations for blockage
  3. Note the code for the technician
  4. Call a technician - pressure switch wiring and calibration are professional diagnostics; never jumper a pressure switch

Parts that commonly fix the 43 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.