What the 45 code means

Control circuitry lockout (on some Carrier service labels worded 'replace control'). The control board has detected an internal failure - a flame sense circuit failure, a gas valve relay stuck open, or a software check error. It auto-resets after a 1-hour lockout; resetting power clears the lockout, and the manual says to replace the control if the code repeats.

Likely causes

  1. Flame sense circuit failure on the control board
  2. Gas valve relay stuck open
  3. Software check error in the control

How to fix it — step by step

  1. Turn power off at the service switch for one minute, then back on once to clear the lockout
  2. Note whether the code returns and how quickly
  3. Do not keep cycling power if 45 comes back
  4. Call a technician - a repeating 45 means the control board needs replacement

Parts that commonly fix the 45 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.