What the 14.3 code means

Flame lost lockout on Carrier furnaces with the 3-digit status display, such as the 58SC0B/58SC1B. The LED flashes major code 14 while the display reads 14.3: the flame signal was lost seven times during a single heat request.

Likely causes

  1. Incorrect manifold pressure or gas firing rate
  2. Gas inlet pressure fluctuations
  3. Flame sensing problem (see codes 34.2-34.3 on display models)

How to fix it — step by step

  1. Check that the air filter is clean and vents are open
  2. Note the code for the technician
  3. Do not repeatedly reset the furnace
  4. Call a technician - seven flame losses in one call is a combustion fault that must be diagnosed

Parts that commonly fix the 14.3 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.