Carrier Furnace 42 Error Code

What the 42 code means

Inducer motor fault on Carrier variable-speed two-stage furnaces such as the 58MVP/58UVB. The inducer did not start within about 20 seconds of a call for heat, its RPM is outside the valid range, or its RPM signal was lost during operation.

Likely causes

  1. Failed inducer motor
  2. Restricted combustion air supply or vent
  3. Improper vent sizing
  4. Loose or damaged inducer motor wiring

How to fix it — step by step

  1. Check the outdoor intake and exhaust pipes for snow, ice or debris and clear what you can reach
  2. Note the code for the technician
  3. Cycle power once at the service switch
  4. If 42 returns, call a technician - a furnace that cannot run its inducer cannot vent combustion gases safely

Parts that commonly fix the 42 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Carrier furnace error codes

See all Carrier furnace codes & guides →