Carrier Furnace 41 Error Code

What the 41 code means

Blower motor fault on Carrier variable-speed furnaces such as the 58CVA/58MVP. The blower failed to reach 250 RPM or failed to communicate with the control within the allowed time (30 seconds after being turned on, or 10 seconds during steady operation).

Likely causes

  1. Failed blower motor or motor module
  2. Loose blower motor wiring or communication connection
  3. Jammed or seized blower wheel

How to fix it — step by step

  1. Make sure the blower access door is fully closed and latched
  2. Turn power off at the service switch for one minute, then back on once
  3. Check the air filter - a severely clogged filter strains the blower
  4. If 41 returns, call a technician - variable-speed blower motors need professional testing

Parts that commonly fix the 41 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.