Carrier Furnace 21 Error Code
What the 21 code means
Gas heating lockout. On Carrier 58-series furnaces, code 21 means the control sensed voltage on the gas valve when it should not be there, so it can no longer guarantee the valve will stay shut. This lockout does NOT auto-reset.
Likely causes
- Gas valve relay stuck closed on the control board
- Mis-wired gas valve
- Short in the gas valve wiring
How to fix it — step by step
- Turn the furnace off at the service switch and leave it off
- Do not repeatedly cycle power trying to clear this code
- Do not touch the gas valve or its wiring
- Call a technician - the control board or gas valve circuit must be tested and repaired
Parts that commonly fix the 21 code
- control board - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.