Carrier Furnace 25 Error Code

What the 25 code means

Invalid model selection or setup error on Carrier variable-speed two-stage furnaces such as the 58CVA/58MVP. The model plug is missing or incorrect, or a setup switch (SW1-1 or SW1-6) is in the wrong position - a fault that usually appears right after a control board replacement.

Likely causes

  1. Model plug missing or incorrect for the furnace
  2. Setup switch SW1-1 or SW1-6 left in the wrong position
  3. Wrong replacement control board installed

How to fix it — step by step

  1. Note the code and when it first appeared (especially if a board was just replaced)
  2. Do not move setup switches or swap plugs yourself
  3. Cycle power once at the service switch; if 25 returns, stop
  4. Call the technician who serviced the furnace to fit the correct model plug and set the switches

Parts that commonly fix the 25 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Carrier furnace error codes

See all Carrier furnace codes & guides →