Carrier Furnace 15 Error Code

What the 15 code means

Blower motor lockout on Carrier variable-speed two-stage furnaces such as the 58CVA/58MVP. The blower failed to reach 250 RPM or failed to communicate with the control within 30 seconds of being turned on, in two successive heating cycles. The control auto-resets after 3 hours; see code 41.

Likely causes

  1. Failed variable-speed blower motor or motor module
  2. Loose or damaged blower motor wiring or communication harness

How to fix it — step by step

  1. Make sure the blower access door is fully closed and latched - the door switch cuts blower power
  2. Turn power off at the service switch for one minute, then back on once
  3. Do not open the blower compartment or test the motor yourself
  4. Call a technician if 15 returns - ECM blower motors and modules need professional testing

Parts that commonly fix the 15 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.