Bryant Furnace 13 Error Code

What the 13 code means

Limit or flame rollout switch lockout. On Bryant furnaces, code 13 means a switch in the limit circuit stayed open too long (or tripped repeatedly in one cycle), so the control locked out; ignition and limit lockouts reset themselves after about 3 hours. See code 33 for the underlying fault.

Likely causes

  1. Repeated overheating from restricted airflow (dirty filter, blocked ducts)
  2. Flame rollout switch tripped
  3. Defective limit switch or loose connections

How to fix it — step by step

  1. Turn the thermostat down and let the furnace cool completely
  2. Check the air filter and replace it if dirty
  3. Open all supply registers and clear blocked return grilles
  4. Wait for the 3-hour auto-reset or cycle power once at the service switch
  5. If 13 returns, stop resetting and call a technician - a tripped rollout switch must be diagnosed, never just reset

Parts that commonly fix the 13 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Bryant furnace error codes

See all Bryant furnace codes & guides →