Bryant Furnace Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 26 codes covered.
Shop Bryant Furnace parts at RepairClinic
- 10.1 — L1 polarity fault on Bryant furnaces with a 3-digit status display, such as the 926TC and 912SE. The LED flashes rapidly and the display…
- 11 — No previous code. On Bryant furnaces with the two-digit LED status code system, code 11 means no fault is stored in the control's memory…
- 12 — Blower on after power up on most Bryant furnaces: if power is restored while the thermostat is calling for heat, the blower runs for about…
- 13 — Limit or flame rollout switch lockout. On Bryant furnaces, code 13 means a switch in the limit circuit stayed open too long (or tripped…
- 14 — Ignition lockout. On Bryant furnaces, code 14 means the furnace failed to light after repeated ignition attempts (four failed tries) and…
- 14.2 — Flame lost on Bryant furnaces with a 3-digit status display, such as the 926TC and 912SE. The LED flashes major code 14 while the display…
- 15.1 — Blower RPM lockout on Bryant variable-speed furnaces such as the 926TC. The LED flashes major code 15 while the display reads 15.1: the…
- 19.1 — InteliSense communication loss on Bryant furnaces such as the 926TC that use an ecobee for Bryant thermostat. The LED flashes 1 short and 9…
- 21 — Gas heating lockout. On Bryant furnaces, code 21 means the control sensed voltage on the gas valve when it should not be there, so it can…
- 22 — Abnormal flame-proving signal (false flame). On Bryant furnaces, code 22 means flame is being sensed while the gas valve is de-energized…
- 23 — Pressure switch did not open. On Bryant furnaces, code 23 means the vent pressure switch was still closed when the control expected it to…
- 24 — Secondary voltage fuse is open. On Bryant furnaces, code 24 means the fuse protecting the 24 V secondary circuit on the control board has…
- 25.1 — No program information in the control's microprocessor, on Bryant furnaces with a 3-digit status display such as the 926TC and 912SE. The…
- 27 — Super plug program fault on Bryant furnaces with a 3-digit status display, such as the 926TC and 912SE. The program in the super plug is…
- 31 — Pressure switch did not close or reopened. On single-stage Bryant furnaces this is the main vent pressure switch; on two-stage models code…
- 31.2 — Open secondary pressure switch on Bryant furnaces with a 3-digit status display, such as the 912SE. The LED flashes major code 31 while the…
- 32 — Low-heat pressure, draft safeguard or auxiliary limit switch did not close or reopened, on two-stage Bryant furnaces. It is the low-heat…
- 33 — Limit or flame rollout switch is open. On Bryant furnaces, code 33 means a switch in the limit circuit opened - most often because the…
- 34 — Ignition proving failure. On Bryant furnaces, code 34 means flame was not sensed during the ignition trial; the control retries several…
- 41 — Blower motor fault on Bryant furnaces with variable-speed blower motors. The blower did not reach the required speed or lost communication…
- 42 — Inducer motor fault on Bryant furnaces with variable-speed inducer motors; on the Bryant 355MAV diagnostic chart it is worded 'inducer…
- 43 — Low-heat pressure switch open while the high-heat pressure switch is closed, on two-stage Bryant furnaces - a contradictory pressure switch…
- 44 — Blower calibration fault on Bryant variable-speed furnaces such as the 355MAV. The calculated blower speed is below 250 RPM or above 1300…
- 45 — Replace control / control circuitry lockout. On Bryant furnaces, code 45 means the control board has detected a fault in its own…
- 46.1 — Momentary loss of power on Bryant furnaces with a 3-digit status display. The LED flashes major code 46 while the display reads 46.1…
- Rapid flashing — On Bryant furnaces, a status LED that flashes rapidly and continuously with no pause means the line-voltage (115 V) polarity is reversed at…