Bryant Furnace Rapid flashing

What this problem usually means

On Bryant furnaces, a status LED that flashes rapidly and continuously with no pause means the line-voltage (115 V) polarity is reversed at the furnace. The control cannot prove flame with reversed polarity, so the furnace will not run.

Likely causes

  1. Hot and neutral wires reversed at the furnace, a junction box or an outlet
  2. Incorrect 24 V transformer phasing on twinned furnaces

How to fix it — step by step

  1. Note the flash pattern before turning anything off, so you can tell the technician
  2. Turn the furnace off at the service switch and leave it off
  3. Do not open junction boxes or swap wires yourself - this is live 115 V wiring
  4. Call an HVAC technician or electrician to correct the reversed polarity

Parts that commonly fix it

This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.