Bryant Furnace 31 Error Code

What the 31 code means

Pressure switch did not close or reopened. On single-stage Bryant furnaces this is the main vent pressure switch; on two-stage models code 31 is the high-heat pressure switch. If the switch stays open too long, the inducer shuts off and retries later.

Likely causes

  1. Blocked or restricted intake or exhaust vent (snow, ice, leaves, nest)
  2. Plugged condensate drain or trap
  3. Disconnected or obstructed pressure tubing
  4. Defective inducer motor
  5. Defective pressure switch

How to fix it — step by step

  1. Check the outdoor PVC intake and exhaust pipes and clear any snow, ice, leaves or debris you can reach
  2. Check the condensate drain line and trap for a clog or standing water
  3. Check and replace a dirty air filter
  4. Turn power off for one minute and back on for one retry
  5. If 31 returns, call a technician - never jumper a pressure switch

Parts that commonly fix the 31 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.