Bryant Furnace 33 Error Code

What the 33 code means

Limit or flame rollout switch is open. On Bryant furnaces, code 33 means a switch in the limit circuit opened - most often because the furnace is overheating from poor airflow. If the switch stays open, the code escalates to lockout 13, and a tripped flame rollout switch needs a manual reset after the cause is found.

Likely causes

  1. Dirty filter or restricted duct system
  2. Closed or blocked registers
  3. Defective blower motor or capacitor
  4. Flame rollout switch open from a venting or combustion air problem

How to fix it — step by step

  1. Check the air filter and replace it if dirty - this is the most common cause
  2. Open every supply register and clear blocked return grilles
  3. Let the furnace cool, then cycle power once at the service switch
  4. Check outdoor vent terminations for blockage
  5. If 33 returns, or you suspect the rollout switch tripped, stop and call a technician

Parts that commonly fix the 33 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.