What the 34 code means

Ignition proving failure. On Bryant furnaces, code 34 means flame was not sensed during the ignition trial; the control retries several more times before going to ignition lockout code 14.

Likely causes

  1. Dirty or failed flame sensor
  2. Defective hot surface igniter
  3. Gas valve defective or turned off, or manual shutoff closed
  4. Low inlet gas pressure

How to fix it — step by step

  1. Confirm other gas appliances work, so you know gas service is on
  2. Make sure the manual gas shutoff near the furnace is open
  3. Make sure the furnace access doors are fully closed
  4. Cycle power once at the service switch for one clean retry
  5. If 34 repeats or becomes 14, call a technician - flame sensor and igniter work is inside a live gas appliance

Parts that commonly fix the 34 code