Bryant Furnace 34 Error Code
What the 34 code means
Ignition proving failure. On Bryant furnaces, code 34 means flame was not sensed during the ignition trial; the control retries several more times before going to ignition lockout code 14.
Likely causes
- Dirty or failed flame sensor
- Defective hot surface igniter
- Gas valve defective or turned off, or manual shutoff closed
- Low inlet gas pressure
How to fix it — step by step
- Confirm other gas appliances work, so you know gas service is on
- Make sure the manual gas shutoff near the furnace is open
- Make sure the furnace access doors are fully closed
- Cycle power once at the service switch for one clean retry
- If 34 repeats or becomes 14, call a technician - flame sensor and igniter work is inside a live gas appliance
Parts that commonly fix the 34 code
- flame sensor - Shop at RepairClinic
- hot surface igniter - Shop at RepairClinic
- gas valve - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.